ZCMD21L1R12SCU Product picture Schneider Electric

View all OsiSense XC standard

OsiSense XC standard - ZCMD21L1R12SCU

Miniature range

ZCMD21L1R12SCU Product picture Schneider Electric
View all OsiSense XC standard
OsiSense XC standard - ZCMD21L1R12SCU
Miniature range

LIMIT SWITCH METAL - 1 NO AND 1 NC - ZCMD

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    OsiSense XC
    series name
    Standard format
    product or component type
    Limit switch body
    device short name
    ZCMD
    design
    Miniature
    body type
    Plug-in body
    associated head
    ZCE01
    ZCE02
    ZCE05
    ZCE06
    ZCE07
    ZCE08
    ZCE09
    body material
    Zamak
    number of poles
    2
    contacts type and composition
    1 NC + 1 NO
    contact operation
    Snap action
    Complementary
    product compatibility
    XCMD
    associated connection component
    ZCMC21L1
    ZCMC21E1
    ZCMC21E10
    ZCMC21E2
    ZCMC21E3
    ZCMC21E5
    ZCMC21E7
    electrical connection
    Plug-in without pre-cabled connection
    contacts insulation form
    Zb
    contacts material
    Silver plated contacts
    positive opening
    With
    minimum actuation speed
    0.01 m/min
    contact code designation
    B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
    R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A
    [Ui] rated insulation voltage
    300 V degree of pollution 3 conforming to CSA C22.2 No 14
    300 V degree of pollution 3 conforming to UL 508
    400 V degree of pollution 3 conforming to IEC 60947-5-1
    resistance across terminals
    < 25 mOhm conforming to IEC 60255-7 category 3
    [Uimp] rated impulse withstand voltage
    4 kV conforming to IEC 60664
    4 kV conforming to IEC 60947-1
    short-circuit protection
    6 A cartridge fuse gG
    electrical durability
    5000000 cycles, DC-13 120 V, 1 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    5000000 cycles, DC-13 24 V, 3 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    5000000 cycles, DC-13 48 V, 2 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    width
    30 mm
    height
    50 mm
    depth
    16 mm
    Environment
    ambient air temperature for storage
    -40...70 °C